Dossiers publics PNRG
Informations archivées
La base de données à partir de laquelle les métadonnées du dossier public PNRG ont été extraites est unilingue et n'est pas maintenue activement. Elle contient des informations qui ne sont pas facilement disponibles ailleurs.
Dossier Public 4011
Previous OF publication(s):
Province / Territory: British Columbia
Funding Source: Federal and Provincial
Year of Collection: 2000
# Lake sites: 0
# Stream sites: 908
Survey Area: 12990 km²
NTS Sheet(s): 104J
The regional stream survey for Dease Lake, B.C. (NTS 104J) was conducted during the summer of 2000.
This report presents analytical and statistical data for 48 elements in stream sediments from 908 sample sites, collected at an average density of one sample per 14.3 km². Loss-on-ignition in sediments, and uranium, fluoride, sulphate and pH values in waters from these sites are included in this report. In addition, 213 stream water samples were analyzed for trace and major elements.
Analytical Data
variable | method | detection limit | year of analysis |
---|---|---|---|
Aluminum | ICP | 0.01 pct | 2000 |
Antimony | ICP | 0.02 ppm | 2000 |
Antimony | INAA | 0.1 ppm | 2000 |
Arsenic | ICP | 0.1 ppm | 2000 |
Arsenic | INAA | 0.5 ppm | 2000 |
Barium | ICP | 0.5 ppm | 2000 |
Barium | INAA | 50 ppm | 2000 |
Bismuth | ICP | 0.02 ppm | 2000 |
Bromine | INAA | 0.5 ppm | 2000 |
Cadmium | ICP | 0.01 ppm | 2000 |
Calcium | ICP | 0.01 pct | 2000 |
Cerium | INAA | 5 ppm | 2000 |
Cesium | INAA | 0.5 ppm | 2000 |
Chromium | ICP | 0.5 ppm | 2000 |
Chromium | INAA | 20 ppm | 2000 |
Cobalt | ICP | 0.1 ppm | 2000 |
Cobalt | INAA | 5 ppm | 2000 |
Copper | ICP | 0.01 ppm | 2000 |
Europium | INAA | 1 ppm | 2000 |
Fluorine | ISE | 10 ppm | 2000 |
Gallium | ICP | 0.2 ppm | 2000 |
Gold | ICP | 0.2 ppb | 2000 |
Gold | INAA | 2 ppb | 2000 |
Hafnium | INAA | 1 ppm | 2000 |
Iron | ICP | 0.01 pct | 2000 |
Iron | INAA | 0.2 pct | 2000 |
Lanthanum | ICP | 0.5 ppm | 2000 |
Lanthanum | INAA | 2 ppm | 2000 |
Lead | ICP | 0.01 ppm | 2000 |
Loss-on-ignition | GRAV | 0.1 pct | 2000 |
Lutetium | INAA | 0.2 ppm | 2000 |
Magnesium | ICP | 0.01 pct | 2000 |
Manganese | ICP | 1 ppm | 2000 |
Mercury | ICP | 5 ppb | 2000 |
Molybdenum | ICP | 0.01 ppm | 2000 |
Nickel | ICP | 0.1 ppm | 2000 |
Phosphorus | ICP | 0.001 pct | 2000 |
Potassium | ICP | 0.01 pct | 2000 |
Rubidium | INAA | 5 ppm | 2000 |
Samarium | INAA | 0.1 ppm | 2000 |
Sample Weight | GRAV | 0.01 gms | 2000 |
Scandium | ICP | 0.1 ppm | 2000 |
Scandium | INAA | 0.2 ppm | 2000 |
Selenium | ICP | 0.1 ppm | 2000 |
Silver | ICP | 2 ppb | 2000 |
Sodium | ICP | 0.001 pct | 2000 |
Sodium | INAA | 0.02 pct | 2000 |
Strontium | ICP | 0.5 ppm | 2000 |
Sulphur | ICP | 0.02 pct | 2000 |
Tantalum | INAA | 0.5 ppm | 2000 |
Tellurium | ICP | 0.02 ppm | 2000 |
Terbium | INAA | 0.5 ppm | 2000 |
Thallium | ICP | 0.02 ppm | 2000 |
Thorium | ICP | 0.1 ppm | 2000 |
Thorium | INAA | 0.2 ppm | 2000 |
Titanium | ICP | 0.001 pct | 2000 |
Tungsten | ICP | 0.2 ppm | 2000 |
Tungsten | INAA | 1 ppm | 2000 |
Uranium | ICP | 0.1 ppm | 2000 |
Uranium | INAA | 0.2 ppm | 2000 |
Vanadium | ICP | 2 ppm | 2000 |
Ytterbium | INAA | 2 ppm | 2000 |
Zinc | ICP | 0.1 ppm | 2000 |
variable | method | detection limit | year of analysis |
---|---|---|---|
Aluminum | ICP | 2 ppb | 2000 |
Antimony | ICP | 0.01 ppb | 2000 |
Arsenic | ICP | 0.1 ppb | 2000 |
Barium | ICP | 0.2 ppb | 2000 |
Beryllium | ICP | 0.005 ppb | 2000 |
Boron | ICP | 0.5 ppb | 2000 |
Caesium | ICP | 0.01 ppb | 2000 |
Calcium | ES | 0.02 ppm | 2000 |
Cerium | ICP | 0.01 ppb | 2000 |
Chromium | ICP | 0.1 ppb | 2000 |
Cobalt | ICP | 0.05 ppb | 2000 |
Copper | ICP | 0.1 ppb | 2000 |
Dysprosium | ICP | 0.005 ppb | 2000 |
Erbium | ICP | 0.005 ppb | 2000 |
Fluoride | ISE | 20 ppb | 2000 |
Gadolinium | ICP | 0.005 ppb | 2000 |
Iron | ES | 0.005 ppm | 2000 |
Lanthanum | ICP | 0.01 ppb | 2000 |
Lead | ICP | 0.01 ppb | 2000 |
Lithium | ICP | 0.005 ppb | 2000 |
Magnesium | ES | 0.005 ppm | 2000 |
Manganese | ICP | 0.1 ppb | 2000 |
Molybdenum | ICP | 0.05 ppb | 2000 |
Neodymium | ICP | 0.005 ppb | 2000 |
Nickel | ICP | 0.2 ppb | 2000 |
Potassium | ES | 0.05 ppm | 2000 |
Praseodymium | ICP | 0.005 ppb | 2000 |
Rubidium | ICP | 0.05 ppb | 2000 |
Samarium | ICP | 0.005 ppb | 2000 |
Silicon | ES | 0.02 ppm | 2000 |
Sodium | ES | 0.05 ppm | 2000 |
Strontium | ICP | 0.5 ppb | 2000 |
Sulphate | TURB | 1 ppm | 2000 |
Titanium | ICP | 0.5 ppb | 2000 |
Uranium | LIF | 0.05 ppb | 2000 |
Uranium | ICP | 0.005 ppb | 2000 |
Vanadium | ICP | 0.1 ppb | 2000 |
Ytterbium | ICP | 0.005 ppb | 2000 |
Yttrium | ICP | 0.01 ppb | 2000 |
Zinc | ICP | 0.5 ppb | 2000 |
pH | GCM | 2000 |
- Acknowledgements:
-
In collaboration with the Geological Survey of Canada, the Dease Lake survey was designed and managed by the B.C. Geological Survey Branch. The survey was funded by the Targeted Geoscience Initiative (TGI) and the British Columbia Ministry of Energy and Mines.
P.W.B. Friske and W. Jackaman directed the survey and coordinated the activities of the various contractors, B.C. Geological Survey Branch (BCGS) staff and Geological Survey of Canada (GSC) staff.
- Collection:
-
Contractor and supervisor details for sample collection Category Responsible Party Contractor: McElhanney Consulting Services Ltd., Vancouver, BC Supervisor: W. Jackaman, BCGS - Preparation:
-
Contractor and supervisor details for sample preparation Category Responsible Party Contractor: Bondar Clegg, North Vancouver, BC Supervisor: R.E.W. Lett,BCGS and P.W.B. Friske,GSC - Analysis:
-
Contractor and supervisor details for sample preparation Category Responsible Party Contractor: ACME Analytical Laboratories, Ltd., Vancouver, BC (1) Becquerel Laboratories, Ltd., Mississauga, ON (2) CanTech Laboratories, Inc., Calgary, AB (1) G.S.C. Analytical Method Development, Ottawa, ON (3) Supervisor: (1) R.E.W. Lett, BCGS (2) P.W.B. Friske, GSC (3) G.E.M. Hall,GSC and J.E. Vaive, GSC
- Other information:
-
ICP = ICP-MS
ES = ICP-ES
Waters filtered and analyzed for major and trace elements.
- Date de modification