Analytical Method Metadata

As - PIXE - NONE



Attribute Value
Quantity: Arsenic
Units: ppm
Description:
Determination Limit: 1  ppm
Upper Determination Limit:
Analytical Precision:
Analytical Grouping: As | NONE | PIXE

Analytical Technique:

Hierarchical classification

Technique >> Spectroscopy >> Electromagnetic radiation >> X-ray >> Emission >> Microprobe >> Proton

Children

None


Analytical Decomposition:

Hierarchical classification

Decomposition >> None

Children

None


Associated Analytical Suites:

Index Suite ID Suite Name
1  610     Guelph proton microprobe
Date modified: