Analytical Suite Metadata

Geoscience Lab, (OGS) MRD123 Lithogeochemical Database: wavelength-dispersive XRF of fused glass disks



General Methodology:

Major and minor element values were determined by wavelength-dispersive X-ray fluorescence spectrometry (WD-XRFS) of fused glass disks. Loss-on-ignition (LOI) was determined gravimetrically.

Instrument: unstated

Sample material: solid

Sample weight: unstated


Analytical Technique:

Hierarchical classification

Technique >> Spectroscopy >> Electromagnetic radiation >> X-ray >> Luminescence >> Fluorescence >> WD-XRF

Children

None


Analytical Decomposition:

Hierarchical classification

Decomposition >> None

Children

None


Analytical Methods:

IndexMethod OrderMethod IDQuantityDetection Limit
1  4352     Al2O3_XWF-101  0.01
2  4363     CaO_XWF-101  0.01
3  4381     Fe2O3_XWF-101  0.01
4  4389     K2O_XWF-101  0.01
5  4395     MgO_XWF-101  0.01
6  4398     MnO_XWF-101  0.01
7  4403     Na2O_XWF-101  0.01
8  4411     P2O5_XWF-101  0.01
9  4426     SiO2_XWF-101  0.01
10  10  4439     TiO2_XWF-101  0.01
11  11  4442     Total_XWF-101  0.01

Associated Analytical Packages:

IndexPackage IDPackage Name
1  104     OGS / MRD123 miscellaneous methods
Date modified: