Analytical Suite Metadata

Manitoba Gov't., Dept. of Environment (surface water) alkalinity



Manitoba Government, Dept. of Environment, surface water; alkalinity using radiometer semi-automatic titrator 11

General Methodology:

Alkalinity was titrated to pH 4.5 end point with 0.02N sulphuric acid using a radiometer semi-automatic titrator 11/pH meter M28 equipped with glass electrode G202C and calomel electrode K401.  Water samples were stored at room temperature until analysed.

Instrument:

Sample material: aqueous

Sample weight: unstated


Analytical Technique:

Hierarchical classification

Technique >> Titration

Children

None


Analytical Decomposition:

Hierarchical classification

Decomposition >> None

Children

None


Analytical Methods:

IndexMethod OrderMethod IDQuantityDetection Limit
1  1184     Alk  1

Associated Analytical Packages:

IndexPackage IDPackage Name
1  295     Manitoba Gov't., Dept. of Environment(NGR surface water) (Fe dl = 20ppb)
2  389     Manitoba Gov't., Dept. of Environment(NGR surface water) (Fe dl = 30ppb)
Date modified: