Analytical Suite Metadata

ODM HMC processing and VG counts [#1]



ODM HMC processing and VG counts. The < 0.25 mm fraction of the samples is counted for gold. The > 0.25 mm fractions are sent to the Saskatchewan Research Council for IM processing.

General Methodology:

Overburden Drilling Management indicator mineral grain separation. The sample is split into a series of fractions as a precursor to mineral grain identification. This procedure is slightly different than the standard ODM flow chart.

A split from the bulk sample is disaggregated and screened with a 2 mm and 1 mm and 0.25 mm mesh respectively. Samples are run twice through the shaking table, panned and gold grains are separated, picked and classified according to shape. The samples are sieved to < 0.25 mm (the 0.25-2.00 mm fraction is sent to Saskatchewan Research Council for indicator mineral picking). Weights for the 0.25-2.00 mm fractions are approximated.

(Description taken from Open File 4299)

1 Table Split (kg)
2 Oversize clasts (>2 mm) (kg)
3 Wet sieve (1 and 2 mm) (kg)
4 < 1 mm table feed shaker (kg)
5 < 1 mm table concentrate total (g)
7 < 1 mm table concentrate methylene iodide (M.I.) separation-M.I. light fraction (g)
8 < 1 mm table concentrate methylene iodide heavy fraction ferromagnetic total (g)
9 < 1 mm methylene iodide (M.I.) heavy fraction non-ferromagnetic total (g)
10 < 1 mm M.I. heavy fraction non-ferromagnetic processed split - 0.25 mm (g)
11 < 1 mm M.I. heavy fraction non-ferromagnetic processed split - 0.25 mm (wash) (g)
12 < 1 mm M.I. heavy fraction non-ferromagnetic processed split 0.25-0.5 mm (g)
13 < 1 mm M.I. heavy fraction non-ferromagnetic processed split 0.5-1 mm (g)

 

Instrument: unstated

Sample material: solid

Sample weight: unstated


Analytical Technique:

Hierarchical classification

Technique >> Physical techniques >> Mineral grain separation

Children

None


Analytical Decomposition:

Hierarchical classification

Decomposition >> None

Children

None


Analytical Methods:

IndexMethod OrderMethod IDQuantityDetection Limit
1  6043     Wt_Processed 
2  6044     Wt_OvrSize 
3  6045     Wt_100_200 
4  6206     Wt_TblFeed_lt100 
5  6207     Wt_TblConc_lt_100 
6  6048     Wt_MI_Lght_1 
7  6049     Wt_MI_Hvy_1 
8  6050     Wt_MIHvyNFM_Tot_1 
9  6051     Wt_MINFM_lt_025 
10  10  6217     Wt_HMCNFMlt25_WASH 
11  11  6052     Wt_MIHvyNFM_25_50 
12  12  6053     Wt_MIHvyNFM50_100 

Associated Analytical Packages:

IndexPackage IDPackage Name
1  238     ODM HMC Processing and VG counts  < 0.25 mm fraction