Analytical Suite Metadata

Chemex (lake and stream sediments) LOI



Chemex, lake sediments; LOI

General Methodology:

Loss on ignition was determined using a 500 mg sample.  The sample, weighed into a 30 ml beaker, was placed in a cold muffle furnace and brought up to 500°C over a period of 2 - 3 hours.  The sample was left at this temperature for 4 hours, then allowed to cool to room temperature for weighing.

Instrument: unstated

Sample material: solid

Sample weight: unstated


Analytical Technique:

Hierarchical classification

Technique >> Gravimetry >> Volatilisation >> LOI, 500°C

Children

None


Analytical Decomposition:

Hierarchical classification

Decomposition >> None

Children

None


Analytical Methods:

IndexMethod OrderMethod IDQuantityDetection Limit
1  1012     LOI  1

Associated Analytical Packages:

IndexPackage IDPackage Name
1  147     Chemex (URP lake sediment) AAS (8+Mo), CVAAS (Hg), COL(As), ISE(F), LOI
2  150     Chemex (URP lake sediment) AAS (8+Mo), CVAAS (Hg), COL(As), LOI (detailed description)
3  294     Chemex (NGR lake sed 1983 samples) AAS (8+4), CVAAS (Hg), LOI500, U, ISE( F)
4  364     Chemex (URP lake sediment) AAS(8+Mo+As), LOI
5  365     Chemex (URP lake sediment) AAS(8+Mo+V+As), LOI
6  366     Chemex (URP lake sediment) AAS(8+Mo+As), ISE(F), LOI
7  386     Chemex (NGR lake sediment) AAS (8+4), CVAAS (Hg), LOI500, U
8  387     Chemex (NGR lake sediment, 1982 samples) AAS (8+4), CVAAS (Hg), LOI500, U, ISE(F)
9  416     Chemex (NGR lake sediment) AAS (8+5), CVAAS (Hg), COL(W), LOI, NADNC (U-5**10)
10  417     Chemex (NGR stream sediment)  AAS (8+5), CVAAS (Hg), COL(W), LOI, NADNC (U-5**10)
Date modified: