Analytical Suite Metadata

Barringer (surface water) Chemtrix/Fisher ISE (F)



Barringer, surface water; ion-selective electrode (fluorine), mixed with total ionic strength adjustment buffer solution and measured with a Chemtrix/Fisher Accumet meter using an Orion fluoride electrode

General Methodology:

Fluoride was determined using a specific ion electrode.  An aliquot of the sample was mixed with an equal volume of a TISAB (Total ionic strength adjustment buffer) solution.  The fluoride was measured initially with a Chemtrix and subsequently with a Fisher Accumet expanded scale meter using an Orion fluoride electrode.

Instrument:

Sample material: aqueous

Sample weight: unstated


Analytical Technique:

Hierarchical classification

Technique >> Electrochemical techniques >> Potentiometry >> Ion-specific electrodes

Children

Glass electrode


Analytical Decomposition:

Hierarchical classification

Decomposition >> None

Children

None


Analytical Methods:

IndexMethod OrderMethod IDQuantityDetection Limit
1  1131     F_ISE  20

Associated Analytical Packages:

IndexPackage IDPackage Name
1  143     Barringer (URP surface water, YT, 1976) FLUOR(U), ISE(F), pH
Date modified: