Analytical Suite Metadata

GSC Leco



GSC Ottawa Leco induction furnace, carbonate analysis

General Methodology:

Carbon was analysed using a Leco induction furnace.  Total carbon is reported as the percentage of carbon in the total sample.  Organic carbon is the percentage of carbon after treatment in hot HCl.  Non-organic carbon can be calculated by subtracting “organic carbon” from “total carbon”. The % CaCO3 equivalent can be calculated from ( “Non-org carbon” / 12 ) x 100 (where 100 = atomic weight of CaCO3).

Instrument: unstated

Sample material: solid

Sample weight: unstated


Analytical Technique:

Hierarchical classification

Technique >> Gravimetry >> Combustion >> Induction Furnace

Children

None


Analytical Decomposition:

Hierarchical classification

Decomposition >> None

Children

None


Analytical Methods:

IndexMethod OrderMethod IDQuantityDetection Limit
1  1546     C_total 
2  1547     C_org 

Associated Analytical Packages:

IndexPackage IDPackage Name
1  51     GSC Leco
Date modified: