Electroanalytical methods use electrically conductive probes, called electrodes, to make electrical contact with the analyte solution.  The electrodes are used in conjunction with electric or electronic devices to which they are attached to measure an electrical parameter of the solution.

The electroanalytical methods are divided into categories according to the electric parameters that are measured. The major electroanalytical methods include

 (Braun, R.D.; Britannica Online Encyclopaedia; retrieved from http://www.search.eb.com/eb/article-9110403 17 Sep 2009)



Hierarchical classification

Technique >> Electrochemical techniques

Children

Conductometry | Voltammetry | Electrogravimetry | Coulometry | Amperometry | Potentiometry


Category: Analytical techniques

The different kinds of analytical techniques have been classified hierarchically. Examples: “AAS”, “FA-NA”. Taken from the “Analytical_Techniques_SHARED” database table.


Associated Analytical Suites:

IndexSuite IDSuite Name
1  189     Chemex (surface water) pH (vague)
2  197     Barringer (surface water) Chemtrix meter (pH)
3  201     Barringer (surface water) combination glass-calomel electrode (pH)
4  218     Chemex (surface water) Fisher Accumet pH meter (pH)
5  222     Bondar Clegg (surface water) pH (NGR, YT, 1977)
6  234     GSC Field Camp water analysis
7  340     Barringer (surface water) pH (combination glass-calomel electrode)
8  352     Bondar Clegg (surface water) pH (NGR, BC, 1978-1981)
9  355     Minen Laboratories Limited (surface water) pH
10  373     GSC (surface water) pH (NGR, YT, 1981)
11  385     GSC (surface water) pH (NGR, ON, 1982)
12  394     ACME (surface water) pH – Broadley-James Combination electrode
13  399     Manitoba Gov't., Dept. of Environment (surface water) pH
14  407     Barringer (surface water) pH – Glass-Calomel electrode meter
15  438     Barringer (surface water) pH – Broadley-James Combination electrode meter
16  453     Barringer (surface water) pH – Glass-Calomel electrode meter (NGR, BC, 1986)
17  474     GSC (surface water) pH (NGR, MB, 1985)
18  505     Cantech (surface water) pH – Glass-Calomel electrode meter
19  513     Cantech (surface water) pH –Orion QuiKcheK Pocket Meter
20  514     Cantech (surface water) Conductivity –Orion QuiKcheK Pocket Meter
21  538     Field Camp (surface water) pH and Conductivity
22  660     Bondar Clegg (surface water) pH – Glass-Calomel electrode meter

Associated Analytical Packages:

IndexPackage IDPackage Name
1  138     Chemex (URP surface water) FLUOR(U), ISE(F), pH (vague description)
2  143     Barringer (URP surface water, YT, 1976) FLUOR(U), ISE(F), pH
3  145     Barringer (URP surface water) FT(U), ISE(F), pH
4  155     Chemex (URP surface water) FLUOR(U), ISE(F), pH
5  159     Bondar Clegg (URP surface water) FLUOR(U), ISE(F), pH (1977)
6  162     Field camp water measurements
7  295     Manitoba Gov't., Dept. of Environment(NGR surface water) (Fe dl = 20ppb)
8  368     Barringer (URP surface water, BC, 1978) FLUOR(U), ISE(F), pH
9  376     Bondar Clegg (URP surface water) FLUOR(U), ISE(F), pH (1978-1981)
10  377     Min-En Laboratories Limited (URP surface water) FLUOR(U), ISE(F), pH
11  382     GSC (surface water) Zn, Mn, Fe, Ca, Mg, Na, K, NO3, PO4, SO4, Cl, U, F, pH, alk
12  384     GSC (NGR surface water) AAS(7)), U, C-org, Cl, Br, NO3, SO4, PO4, F, pH, alk
13  388     Acme (NGR surface water) LIF(U), ISE(F), pH
14  389     Manitoba Gov't., Dept. of Environment(NGR surface water) (Fe dl = 30ppb)
15  392     Barringer (NGR surface water) LIF(U), ISE(F), pH (glass-calomel electrode meter)
16  397     Barringer (NGR surface water) LIF(U), ISE(F) and pH (Broadley-James meter)
17  404     Chemex (NGR surface water) LIF(U), ISE(F) and pH
18  410     Barringer (NGR surface water) ISE(F), pH
19  414     Barringer (NGR surface water) LIF(U), ISE(F), pH, ICP(Ca, Mg), Alk
20  418     Bondar Clegg (NGR surface water) LIF(U), ISE(F), pH
21  424     Chemex (NGR surface water) LIF(U), ISE(F), ICP (Ca, Mg), pH and Alk(d.l.=1)
22  425     Chemex (NGR surface water) LIF(U), ISE(F), ICP (Ca, Mg), pH and Alk(d.l.=2)
23  428     Chemex (NGR surface water) LIF(U), ISE(F), AAS (Ca, Mg), pH and Alk (d.l.=1)
24  431     GSC (NGR surface water) Ca, Mg, F, pH, Alk
25  433     Bondar Clegg (NGR surface water) ICP (9), U, F, pH, alk
26  437     Chemex (NGR surface water) LIF(U), ISE(F), pH, alk
27  454     Cantech (NGR surface water) LIF(U), ISE(F), pH
28  464     Cantech (NGR surface water) pH and conductivity
29  473     Cantech (NGR surface water, BC, 2000) pH, U, F, sulphate
30  477     Cantech (NGR surface water) pH and conductivity [UNUSED]
31  480     Cantech (NGR surface water, BC, 2001) pH, U, F, sulphate
32  488     Field Camp (surface water) pH and Conductivity