Analytical Sample Bundle Metadata

1987

NGR-0113-1986-NB-SS-1

Type: lab data



Bundle Download

Download analytical data for this bundle in one of three formats, depending on the desired convention for treating values below the lower detection limit:

Bundle Description

NGR stream sediment analysis, New Brunswick 1986, NTS 21G, 21H, atomic absorption spectroscopy (8 elements + As + Cd + Mo + V +Sn + Sb + Ba), cold vapour (Hg), COL (W), LOI at 500C,F, U(5**10 flux), Bondar Clegg and Company Ltd, Ottawa.

These analytical data are published in GSC OF 1355.

Sample Classification (Analytical)

IndexSample CountSurveySample TypePrep Lab MaterialControl RefUnknown SourceDuplicates count
45     Control Reference Unspecified Yes  No 
840  NGR stream sediment and water survey, parts of NTS 21G, H, southern New Brunswick, 1986 (more) NGR bulk stream sediment <177 micron (NGR) No  No  90 

Analytical Package Description

Laboratory: Bondar Clegg and Company Limited

Name: Bondar Clegg (NGR stream sediment) AAS (8+7), CVAAS (Hg),W, LOI, F, U (more)

Bondar Clegg (National Geochemical Reconnaissance), stream sediment; atomic absorption spectroscopy (8 elements + As + Cd + Mo + V (dl=5ppm) +Sn + Sb + Ba) + atomic absorption spectroscopy (mercury; cold vapour ) + colorimetry (tungsten) + LOI at 500°C + ion-selective electrode (fluorine) + neutron activation-delayed neutron counting (uranium-5**10 flux, Helium detector, 20s, d.l.=0.5 )

Analytical Suites:

IndexName
1  Bondar Clegg (stream sediment) AAS (8 + Cd; air acetylene) ( Mn upper dl = 20,000 ppm)
2  Bondar Clegg (stream sediment) AAS (As; hydride evolution)
3  AAS (Mo,V (dl=5); nitrous oxide acetylene)
4  Bondar Clegg (lake and stream sediment) AAS (Sb; hydride evolution) - 3ml conc
5  Bondar-Clegg Sn AAS
6  Bondar Clegg (stream sediment) AAS (Ba; nitrous oxide)
7  Bondar Clegg (lake and stream sediment) CVAAS (Hg)
8  Bondar Clegg (lake and stream sediment) COL(W)
9  Bondar-Clegg (lake and stream sediment) LOI500
10  Uranium (lake and stream sediment) NADNC ( U – 5**10, He detector, 20s, d.l.=0.5)
11  Bondar-Clegg Fluorine ISE

Analytical Methods:

IndexColumn NameSuite OrderMethod OrderSuite RepeatQuantityUnitsDetermination Limit
1  Zn_AAS    Zn  ppm 2  
2  Cu_AAS    Cu  ppm 2  
3  Pb_AAS    Pb  ppm 2  
4  Ni_AAS    Ni  ppm 2  
5  Co_AAS    Co  ppm 2  
6  Ag_AAS    Ag  ppm 0.2  
7  Mn_AAS    Mn  ppm 5  
8  Fe_AAS    Fe  percent 0.02  
9  Cd_AAS    Cd  ppm 0.2  
10  As_AAS    As  ppm 1  
11  Mo_AAS    Mo  ppm 2  
12  V_AAS    V  ppm 5  
13  Sb_AAS    Sb  ppm 0.2  
14  Sn_AAS    Sn  ppm 1  
15  Ba_AAS    Ba  ppm 40  
16  Hg_CVAAS    Hg  ppb 10  
17  W_Col    W  ppm 2  
18  LOI_500    LOI  percent 1  
19  U_NADNC  10    U  ppm 0.5  
20  F_ISE  11    F  ppm 20  
Date modified: